
The constant volume regulator is an element placed inside the duct in order to obtain a constant flow within a pressure range from 50 to 250 Pascals.
It is used in air conditioning or ventilation systems either in extraction or blowing mode.
Regulator Diameter |
N/A 4 Inch |
Setting |
N/A RDR Ø 100 |
Maximum Temperature |
N/A 60 ºC |
Material |
N/A
Plastic (Classified M1) |
Intermediary Step |
N/A 5 m³/h |
Flow Range |
N/A 30-60 CFM |
Set Flow |
N/A 60 CFM |
Dimension D1 |
N/A 96 mm |
Dimension D2 |
N/A 93 mm |
Dimension L |
N/A 70 mm |
Components |
N/A Air Flow Setting Cale (According to the Air Flow) Piece of Regulation Regulator Casing Screw to Fix the Air Flow Sleave with Lip Seal |
Sound Power Level at 60 Cubic Meter Per Hour (m³/h) Flow and 50 Pascal (Pa) Pressure |
N/A 32 dBA |
Sound Power Level at 60 Cubic Meter Per Hour (m³/h) Flow and 100 Pascal (Pa) Pressure |
N/A 37 dBA |
Sound Power Level at 60 Cubic Meter Per Hour (m³/h) Flow and 150 Pascal (Pa) Pressure |
N/A 39 dBA |
Sound Power Level at 60 Cubic Meter Per Hour (m³/h) Flow and 200 Pascal (Pa) Pressure |
N/A 42 dBA |
Sound Power Level at 75 Cubic Meter Per Hour (m³/h) Flow and 50 Pascal (Pa) Pressure |
N/A 32 dBA |
Sound Power Level at 75 Cubic Meter Per Hour (m³/h) Flow and 100 Pascal (Pa) Pressure |
N/A 37 dBA |
Sound Power Level at 75 Cubic Meter Per Hour (m³/h) Flow and 150 Pascal (Pa) Pressure |
N/A 40 dBA |
Sound Power Level at 75 Cubic Meter Per Hour (m³/h) Flow and 200 Pascal (Pa) Pressure |
N/A 42 dBA |
Sound Power Level at 90 Cubic Meter Per Hour (m³/h) Flow and 50 Pascal (Pa) Pressure |
N/A 32 dBA |
Sound Power Level at 90 Cubic Meter Per Hour (m³/h) Flow and 100 Pascal (Pa) Pressure |
N/A 38 dBA |
Sound Power Level at 90 Cubic Meter Per Hour (m³/h) Flow and 150 Pascal (Pa) Pressure |
N/A 41 dBA |
Sound Power Level at 90 Cubic Meter Per Hour (m³/h) Flow and 200 Pascal (Pa) Pressure |
N/A 44 dBA |
Important |
N/A
|
Presentation |
N/A
The self-adjusting flow regulator RDR can be adjusted on sites according to the requested air flow. |
Adjustment |
N/A
Before setting the regulator, it's necessary to calibrate the flow:
|
Installation |
N/A
The flow regulators are simply fitted into vertical or horizontal ducts. On the horizontal duct, respect the mention «DOWN» indicated at the front of the product. A leap seal ensures the airtightness. |
Characteristics |
N/A
The curves show the flow variations in m³/h of RDR Ø 150, 160 and 200 mm in extraction according to the difference of pressure in Pascal (pressure range of 50 to 250 Pa). The values given are averages which may vary of:
Flow regulators are characterized by their noise level in dB(A). |